Title
-
EWP 6-3-3 Douglas Elementary 1957-1958 5
-
Tag
-
Lectro Speed Booster, electric water heater, S.W. Stinemetz, hotels, restaurants, schools, hospitals, churches, institutions, Washington D.C., galvanized steel
-
PII
-
Place
-
Virginia
-
Identifier
-
1026592
-
Is Version Of
-
1026592_EWP_6-3-3_Douglas_Elementary_1957-1958_5.pdf
-
Is Part Of
-
Uncategorized
-
Date Created
-
2024-01-07
-
Format
-
Pdf Document
-
Number
-
09bc808d939d3d14164bed6641cd18d661d6b26895b02fc66ba7594ada55196e
-
Source
-
/Volumes/T7 Shield/EWP/Elements/EWP_Files/Access Files/Upload temp/1026592_EWP_6-3-3_Douglas_Elementary_1957-1958_5.pdf
-
Publisher
-
Digitized by Edwin Washington Project
-
Rights
-
Loudoun County Public Schools
-
Language
-
English
-
Replaces
-
/Volumes/T7 Shield/EWP/Elements/EWP_Files/source/Ingest One/6 Students and Scholarships/6-3-3 Scans of Teacher Term Reports/6-3-3 Douglass Elementary/6-3-3_Douglas_Elementary_1957-1958_Manufacturers Spec Sheets/EWP_6-3-3_Douglas_Elementary_1957-1958_5.pdf
-
extracted text
-
#WffiW
ffiffiffiffitu
ffiffiffi.
$*
f
!;'
*
oa
A
cI.
is
C.{
iir.i
I
e
0 c
ETECTRIC WATER HEATERS
lj a) -, i.-' !-l l_l a-) i',) ,,) .-l t_',,_l -, l-) r,l ,-lr i, .- i.-l ,,; .,
30]D
BY
,lnor€
";
-i, "*
Fli','*,t1.
ri.
\1.1
1..
i11
,
',
: l, irrg:fi
, ,.1 r, i
ii{'I rn. 5,!l i,'ii-''l i!:.1.
ii']t?i* = $grim ' it:j,ifl"
, $Ju$$*iia'r
'"
,t{
\ !" i:l:
rd;:
a,,
I
n
O
f,
H
N
E
El
n
15
H
TJ
Ltr
>)
E
H
H
N
ht
n
ffi
F
iNE
w
TI
H
Lt=J
H
>)
r{
T
H
a
E
H
>)
H
n
H
H
il
N
N
H
N
d
,,
lr
I
I>)
I
Irl
;
H
d
N
6
N
E
nT
N
ffi
H
!J
Lrd
t.l
6
&
xxi\i^
A
^
^
x/ x \
oo
)
CO
^\
\
2>xw^
* x i\
aX11a
<
x
AX
x 4 X x
TANK: 5/16" seomlessiube 6It - 8't - 10" - I2" diqmeter.
BACK HEAD: /2" steel plote.
FRONT HEAD: l" steel plote.
CASING: 22 go. cold rolled steel with white boked
enomel finish.
All tonk bodies ore golvonized ofter complete fobricotion.
Spocer ring equolizing lhe dislonce between cosing ond
tonk body is supported 6y \Ya" xVe" x2" slrips welded to
tonk body ond connecled by I le" x ya" bond iron ond
welded.
Supporting brocket for entire ossembly is mode of 1Ya x
1Ya x % ongle iron, connecled over the top by 1Ye x yB
bqnd iron. These 2 pieces held logelher with Ta x h
mochine screws.
Model
Wottoge--,-,-.------...-----.
Voltoge.,.-.....-----.--..-...
Cop. Gol.--.-.---,.--.....--.
5B
5B
5KW
208V
230V
6KW
208V
230V
I.PH
I -PH
I
3098
9KW
208V
230V
or 3-PH
l2KW
3l58
l5KW
208V
230V
or 3-PH
208V
230V
or 3-PH
3',t28
I
I
Welding done by certified welders.
Entire unit insuloted with
All elements by Chromolox or equql.
Aquostots ore Wilcolotors R-2; roted 26 omps @ 230V;
AC only.
Supply & dischorge pipe - 3/t". Droin pipe Yz".
Moximum temperoture 194"F. qs per underwrilers'Code.
Boosler copocity is bosed on on incoming woler lemperof I40oF.
oture
All Boosters U. L. opproved - ASME constructed
ing pressure 150 P.S.l. Tesr 600 P.S.l.
31
8B
lSKW
208V
230V
I or 3-PH
I
4208
20KW
208V
230V
or 3-PH
7t/2
I
1218
24KW
208V
230V
or 3-PH
7t/z
4308
30KW
208V
1368
36KW
208V
I or 3-PH
I
545B
or 3-PH
-
Work
45KW
5548
54KW
208V
236V
3.PH ONIY
236V
3-PH ONI-Y
208v
3
3
41/2
41/2
1V2
4V2
7V2
7V2
,....-----.
17065
20475
30717
409s6
5l I95
6t a34
68260
819r 2
102390
122464
153585
1RA?f}t
lnches.---.-.--- -.---.
11x29
11x29
14x29
13x29
13x29
13x29
15x29
15x29
15x29
| 5x29
I613O
r^-?n
50
60
120
I50
180
135
t35
90
207
2r0
212
214
200
225
240
235
300
245
360
250
450
270
540
270
B.T.U. per H.
-
Overoll Size
in
2" Fibergloss insulolion.
l2
12
Gdl. per Hr.
40'
Rise.--.............
Shippins Wt.. ---,...,.Booslers
of lorger size on
requesl?
or booslers in series moy be
used,
BOOSTER AMPERA,GE
FOR CONTACTOR SIZING (AMPS DRAWN PER t)
K.W
SINGI.E
PHASE
THREE
PHASE
5KW
9KW
l2KW
r5KW
l8KW
20KW
24KW
30KW
36KW
45KW
54KW
208
24
13
58
72
87
96
ll5
144
173
23
41
54
68
82
9l
l09
136
164
216
201
259
220
208
11
25
33
42
50
56
67
83
I00
125
150
220
14
21
32
39
47
53
63
79
95
ll8
142
t
216
l\
Drt
-w
F
I
I
l
I
N
I
I
I
I
I
I
\
I
I
BO
I
I
\
I
I
E"
\--
I
I
-1.-
I
- --'
t;
I
G,,
BOOSTER
NUMBER
5B
5B
5KW
5KW
208V
230V
208V
230V
I.PH
I
i -PH
3l 2B
3098
9KW
208V
230V
or 3-PH
I
3l 5B
l2KW
l5KW
208V
230V
or 3-PH
208V
230V
or 3-PH
I
I
3l 8B
rSKW
208V
230V
or 3-PH
I
4208
20KW
208V
230V
or 3-PH
I
4248
24KW
208V
230V
or 3-PH
I
4308
30KW
208V
230V
or 3-PH
I
5458
5548
45KW
54KW
208V
208V
236V
236V
3.PH ONLY 3-PH ONTY
4368
35KW
208V
230V
or 3-PH
A"
28Y2
28Y2
28Y2
28Y2
28Y2
B''
II
ll
'13
l3
c"
4
4
4
4
D"
7
7
7
7
7
7
7
7
7
E''
SYz
5Y2
6Y2
5Y2
6Y2
61/z
7y2
7Ya
7y2
F"
7
7
7
7
7
7
7
7
7
7
7
13Y2
13y2
17h
l7Y2
17h
17y2
1AY2
18Y2
1
1Va
1
5Y2
'l
28Y2
28Y2
l3
4
51/2
1
28y2
28Y2
28Yz
3OY2
3OY2
I3
'15
15
'15
I5
l6
t6
4
4
4
4
4
4
4
7
7
7
7Y2
d
5y2
I
f
Fis.
L
Fis.
1
2
.o
LI
L1
Fis.
f-1
3
TYPICAL
WIRING
-o
DIAGRAMS
*o
.-@
@*
I
I
I
L
,a
58
Fis. 4
-
I
3098-lPH.3r2B-lPH
IPH
Lr Ll !a
l
I : Aquostot *
26 Amp @ 230 Volts
2 : Elements
3 - Disconnect switchnot f urnished
4 : Conloctor not furnished
-€
Fig.
5
L' L1
L3
3l5B - IPH ond Lorger
--o
+@
3098
-
3PH
L' L'
Fig. 6
d -|1r
@*
b
V
3128, 3158,
3l8B -
3PH
tI
3208
-o
-
3PH ond Lorger
PTUMBING INSTRUCTIONS
A suitoble sofety device (such os o temperoture pressure relief mechsnism which
complies with lhe locol plumbing or building code) should be connected to the heqter
ot ihe time it is instolled.
Provisions qre msde to instqll pressure ond temperoture relief volves os
piping loyout.
in
.)
Booster
NOTE: Relief volves should never be locoted where they ore subiect to o freezing
temperoture. Their proper instqllotion will prevent the possibilily of on excessive
woter pressure.
Locote woter heoter neor dishwosher or outlet most used.
To goin the utmost economy of operotion it is odvisoble to insulote the hot woter
pipe, especiolly where these qre long exposed lengths between booster ond outlet.
Woter pressure should noi exceed 30 pounds per squore inch.
Droin volve should be instolled os in plumbing diogrom.
WIRING INSTRUCTIONS
/
Heoter is completely wired with leods to terminol box.
Use proper wire size, check nqme plote for correct voltoge, phose, wottoge os
stomped on plote fostened over terminol box.
Be sure tonk is
See
filled with woter before turning on electricity.
wiring diogroms os in pomphlet.
When droining tqnk turn off electricity.
Coll your deoler's service deportment
soiisfoctory.
if for ony
reoson hot woter service is not
Heoter is guoronteed for one yeor ogoinst defective ports or workmonship.
During the first yeor from dqte of originol purchose, should ihe heoter prove to be
defective due to defective pcrts or workmonship thot it must be returned to foctory,
Applionce Building Compony, lnc. will repoir or supply o new one free of chorge.
Your expense is the tronsportotion. to snd from the foctory ond minor disconnections qnd instollotion chorges.
This guorontee does not opply to domoge resulting from excessive voltoge, mechonicol domoge, occidents, qlteroiions, freezing, misuse, or for ctny reason other thon
defective workmonship or mqteriol.
)
W
il.lfr.TfitdiUfTfil
I
1
D/,9H -WASHER
ooosrER
l.
Supply from woler heoter-minimum temperoture 140".
2.
Pressure reducing
vqlve-moximum setting 30 lbs.
3. Swing check volve. (Furnished)
4.
Booster drqin-y2" hose bibb. (Furnished)
5. Booster
surge pipe- 3/t', with cop (moke high os possible).
6. Temperoture pressure relief vqlve 212'T, l2s lbs. pressure. (Furnished)
7. Supply to dish wosher minimum temperoture .l80'.
8. Droin from relief volve to floor droin. Note: lt is ogoinst oll
into ony sink or open contoiner.
9. Temperoture
10. Pilot lisht.
U
codes
pressure guoge.
(Furnished)
NOTE: Any deviotion of the plumbing or wiring diogrom voids the guqrqntee
ond qbsolves .A,pplionce Building Compony of ony subsequent domoges.
to dischorge this pipe
APPTIANCE BUILDING COMPANY INC.
6505 SEAVIEW AVENUE
.
SEATTTE
7, WASHINGTON
HEmlock 3304
ffi
GAL.
KILO.
WT.
OUTSIDE
CAP.
WATTS
LBS.
DIMENSIONS
J
a
5KW
r35
1
1x29
3
6KW
r35
1
1x29
5B
4rt
6KW 3d
207
13x29
5BS
20
6to'IBKW
I 15
22x29
309B
4Vz
9KW
207
13x29
3128
4Yz
t 2KW
210
13x29
3r5B
4Vz
I 5KW
212
13x29
3r8B
4,/z
1
8KW
214
13x29
4208
71/z
2OKW
22s
1
4248
71/,
24KW
235
| 5x29
430B
7Yz
30KW
245
| 5x29
12
36KW
262
I
6x30
*545B
12
45KW
280
I
6x30
*,*5548
12
54KW
300
1
6x30
MODEL
*5B
5B
**
*
4368
PRICE
5x29
MAGNETIC CONTACTORS
- lsKW & over
For three phose - 20KW & over
Add
For Single phose
Add
Smoller models hqve built in contoctor.
*Avoiloble in single phose only. All other models ovoiloble in single or three phose
236 or 208 volts.
** Avoiloble in three phose only except on speciol quote.
Booster Heoters ore U. L. opproved.
All models hove o siond supplied which permils horizontol or verticle mounting.
(Add 4t/2" ro Dio" for totol height.)
A
3/a
temperoiure ond pressure relief volve
ond